VMD Industrial 3-in-1 Dehumidifying Dryer For Mould

  1. Home
  2. >

Details

VMD Industrial 3-in-1 Dehumidifying Dryer For Mould

Integrated dehumidifying, drying and feeding into one unit.

Standard configuration is 1 to 2 feeding: 1 reed switch hopper and 1 photoelectric hopper

Optional configuration is 1 to 3 feeding: 1 reed switch hopper and 2 photoelectric hoppers

Up to 1 to 4 feeding: 1 reed switch hopper and 3 photoelectric hoppers

Controlled by microprocessor with P.I.D. temperature control.

Consists of LCD display and keyboard.

Double-condenser provides lower return air temperature and dew point below -40°C (-50°C is realizable with chilling water).

Easy to operate system and to understand warning messages.

Insulating drying hopper with European standard allows better heat preservation and drying efficiency.

Fully sealed feeding system to prevent dried material from contacting open air and being re-damped.

Discharge valve ensures no residual materials in hopper tubes.

Small footprint and high movability.

PLC control with enhanced configuration is optional for feeding up to 5 molding machines.

Can be paired with a dew-point monitor.

industrial dehumidifier
industrial dehumidifier
Dehumidifying Dryer For Mould
Dehumidifying Dryer For Mould
3-in-1 Dehumidifying Dryer
3-in-1 Dehumidifying Dryer
Industrial Dehumidifying Dryer
Industrial Dehumidifying Dryer
Model VMD-45L

/50A

VMD-90L

/80A

VMD-120L

/80A

VMD-160L

/130A

VMD-230L

/160A

VMD-300L

/220A

VMD-450L

/300A

VMD-750L

/400A

VMD-900L

/500A

VMD-1200L

/80A

Hopper Capacity(L) 45 90 120 160 230 300 450 750 900 1200
Insulating

Materials

Fiberglass and Casing
Dry Air Dew Point -40°C
Drying Temp. 80-160°C
Air Flow(m3/h) 50 80 80 130 160 220 300 400 500 800
Blower Power(kW) 0.55 0.75 0.75 1.1 1.5 2.2 3 5.5 5.5 7.6
Regeneration Blower

(kW)

0.25 0.25 0.25 0.25 0.55 0.55 0.75 0.75 2.2 2.2
Drying Heater(kW) 3.9 5.4 5.4 5.4 7.2 12 15 18 21 21
Regeneration Heater

(kW)

3.9 3.9 3.9 3.9 5.4 5.4 7.2 7.2 11 14
Pipe

Diameter

Drying

(mm)

38 51 51 51 63 63 76 76 100 100
Cooling

(inch)

3/4〞
Regeneration(mm) 38 38 38 38 51 51 51 51 63 63
Conveying Blower(kW) 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 3.7 3.7
Conveying

Distance

(m)

Stage 1 10
Stage 2 10
Hose Diam.(inch) 1.5 2 2
Sensor Hopper

Capacity(L)

6 6 6 6 6 6 6 10 10 10
Vacuum Hopper

Capacity(L)

6 6 6 6 6 6 6 10 10 10
Dimension

L×W×H(cm)

110×93×
160
113×93×
232
113×93×240 113×
93×270
137×
99×275
137×
99×275
150×
130×285
178×
130×292
214×
138×322
225×
138×355
Net Weight(kg) 280 310 340 360 420 550 600 750 830 900

Note: the minimum air pressure is 0.4MPa and the minimum air flow is 15L/hr.

Power supply: 3Φ 380VAC 50Hz